Creosote Sweeping Log
 
My Email

My Question

Characters left

* Questions are answered in 1-2 business days.
* Questions may be published (We do not post email addresses)
* Spammers will be blocked
Send this page to a friend
To
From
Subject
Message
Characters left
 
Send a notification when available
 
My Email


* You will receive a notification when this product is available.

Creosote Sweeping Log

Home > Home & Garden > Maintenance > Creosote Sweeping Log

Creosote Sweeping Log

Images

Creosote Sweeping Log
   

Videos

Product DemoProduct Demo
$16.95/each
Reg. $24.99

Quantity


As Seen on TV Item

Sku: 98382
 (3 Reviews)


Shipping Weight: 
3 lbs 1 oz
Dimensions: 
12.00"W X 4.00"H X 4.00"D

Description

Creosote Sweeping Log (CSL) burns like a standard fireplace log, while simultaneously helps reduce dangerous creosote build-up. Great for fireplaces and woodstoves!

Now a CSIA (Chimney Safety Institute of America) accepted product. Tested by Omni Laboratories. UL Approved.

CSL - How it works: The Creosote Sweeping Log burns for approximately 90 minutes, during which it heats the tar on your chimney wall to an ideal treatment temperature. The smoke from CSL is charged with minerals, which are deposited onto the creosote over a several hour period . During the next 15 days, the CSL treatment will continue to work and the creosote will gradually become brittle and break away. Any deposits that remain, will be rendered less flammable.

Compatibility: The Creosote Sweeping Log is designed to work on any kind of chimney, including stainless steel. CSL may also be used in combination wood/oil burning furnaces.

Features
  • Treats and reduces existing creosote in your chimney.
  • Stops more than 50% of new creosote build up.
  • Accepted by CSIA - Chimney Safety Institute of America.

Instructions

Before Using the CSL:

Prior to using the CSL, always perform a visual inspection of your chimney and flue to ensure that it is free of debris, bird's nests, or other obstructions.

Do not use the CSL as your first fire of the season. Burn normal fires for twoor three days prior to CSL application.

Ensure that the fireplace damper is fully open.

If you have a catalytic combustor, close it with the bypass and put it in the inactive position. Leave the catalytic combustor in bypass mode for 1 to 2 weeks, the duration of the treatment period. See page 12 for more information regarding catalytic combustors.

The CSL is non corrosive and will not damage flue pipes. It is safe to use with all masonry chimneys.

The CSL may be used with woodstoves, wood burning furnaces, fireplace insert, wood burning fireplace with a gas starter, wood/coal stove, boilers, dual fuel wood burning boilers or furnaces and fireplaces.

Do not use the CSL with artificial gas or electrical fireplaces or BBQs. It also should not be used on oil only burning furnaces.

Getting started

To ensure proper combustion of the CSL, pull the seams of the wrapper outward, to create an airspace between the CSL and the paper. This will allow it to catch fire more efficiently.

For Woodstoves, inserts and small fireplaces, use 1 CSL:


For best results, place the CSL on the hot embers after you have burned a regular fire.

Never place the CSL on an active fire.

The CSL will work alone, however, placing the CSL on the hot embers will help prevent downdrafts (smoke coming back down the chimney) when the smoking action of the

CSL process continues after the flames have died out. Go to facts and tips menu for more information on downdrafts.


For large fireplaces or when using 2 CSL at the same time:

Remove the two CSLs from the box and place them both in your fireplace.

DO NOT place the two CSL's on hot embers. Placing two CSL logs on hot embers may cause the fire to burn too intensely.

If a downdraft occurs, it is most often caused by poor draft conditions within the room.

Open a window or door and if necessary, carefully place some paper in the fireplace to tart the draft going upwards again.

Make sure all fans (heating, ceiling, etc.) are shut off when using the CSL, even fans in others rooms such as the bathroom or kitchen.

If the CSL does not ignite, light each ends with a match or lighter. Do not use flammable liquids or other means to ignite the log.

Close any glass doors and lower air-intakes on your wood burning appliance.

Close any fire protection screens.

Using the CSL with a woodstove or fireplace insert

Woodstoves are well known to produce high amounts of creosote inside the flue pipes.

Burning only one CSL in a wood stove or fireplace insert will reduce overall creosote weight, thickness & volatile organic compounds. Therefore, to keep your woodstove or fireplace insert in good condition, follow the guidelines in the chart below according to your woodstove or fireplace insert usage.

Creosote build-up will depend on appliance type, fuel used, frequency of use and other factors.

For Woodstoves, inserts and small fireplaces, use 1 CSL at a time:

For best results, place the CSL on the hot embers after you have burned a regular fire. Never place the CSL on an active fire.

Regular chimney inspections are always recommended. The CSL will not tell you if your chimney is blocked or has any kind of structural damage. The CSL does not take the place of inspection and professional cleaning.



Using the CSL with a fireplace
Fireplace chimneys produce less creosote but they are often harder to clean.

Due to a high air flow draft, open fireplaces produce less creosote than a woodstove. Still, it needs your attention over time. Therefore, use CSL to render creosote more brittle for easier mechanical cleaning, as well as to lower volatile organic compounds in your chimney.

A small fireplace has a horizontal opening that is less than three feet. A large fireplace has a horizontal opening that is wider than three feet.

For large fireplaces or when using 2 CSL at the same time:


Remove the two CSLs from the box and place them both in your fireplace.

DO NOT place the two CSLs on hot embers. Placing two CSL logs on hot embers maycause the fire to burn too intensely.

Regular chimney inspections are always recommended. The CSL will not tell you if your chimney is blocked or has any kind of structural damage. The CSL does not take the place of inspection and professional cleaning.

How it Works

The combustion process when wood is burned is never complete. The smoke from a wood fire usually contains a dark brown or black substance which has a smoky odor. This tar like substance is called creosote, and it is found nearly everywhere in a wood heating system.

Wood has different characteristics. Certain types of wood release more heat than others. Hardwoods, such as oak, are denser than softwoods such as pine. Hardwoods will burn longer. Unseasoned green wood will burn with difficulty and produce more creosote.

Each time you burn a wood fire creosote is formed. Over time, it will build up inside your chimney. Creosote is a flammable material which can ignite causing a fire up in your chimney.

The CSL contains a mixture of special additives that are dispersed during the process of burning. The additives are released through the smoke and adhere to the creosote. A chemical reaction will take place for one to two weeks. During this time, the creosote may become brittle.

You continue to use your appliance, the heat from the fires will treat the creosote and may cause the creosote to disperse as a fine powder, or break away from the chimney wall and fall back into the firebox in the form of small particles.

Any remaining creosote is less likely to result in a chimney fire. It also is more brittle, allowing for easier and more effective mechanical removal.

After you have used the CSL

The CSL will continue to smoke even after the flames have gone out. This is a normal part of the application process.

After you have used the CSL, make sure your damper is left fully open, until the smoking has completely stopped.

Falling creosote can come down over a period of days and is often difficult to distinguish from regular fire ashes.

If possible, allow a few hours between using the CSL and starting another fire.

After you have used the CSL, it is beneficial to have subsequent wood fires every couple of days for the next one to two weeks. This will allow the additives released by the CSL to further treat the creosote.

If your wood burning appliance is used constantly, much of the flaking creosote will be dispersed from the heat and draft of continuous fires.


Wait 1 to 2 weeks after using the CSL before doing a mechanical sweeping, as the creosote will be easier to remove after the treatment is complete.

Caution - Safety


Do not use the CSL in gas or propane stoves, BBQs, or oil only burning furnaces.

Do not use for cooking.

Poking or breaking up of the CSL while it is burning may cause it to burn too intensely. Flaming particles may stick to fireplace tools. Do not add wood or other material to the fire after you have placed the CSL into the firebox.

Do not attempt to remove a burning or smoldering log from the fireplace.

In a woodstove or fireplace insert, burn only one CSL at a time.

Leave any remaining residue from the CSL in the firebox. Additives will continue to be released, and any remaining unburned residue will be reduced to ashes as you burn your next fire.

Do not close the fireplace damper until the ashes are cool and there is no further smoking activity.

Inspect both the top of the damper and smoke shelf (if equipped) from time to time to ensure they are cleared of fallen creosote particles after use of the CSL. This is particularly important if your creosote build up was significant before using the CSL. Remove the debris with a curved brush or a wet/dry-vac type vacuum cleaner.

If your woodstove has an angled or horizontal flue, inspect and clean any debris which may collect in it.

Installing a regular chimney cap can often solve downdrafts caused by winds. Check at www.cleanyourchimney.com or more details

Open a window (on the side of the house the wind is blowing against) if there is little air in the room with the fireplace.

In an emergency you can extinguish the CSL. Use a UL listed chemical fire extinguisher or carefully do use it with water.

Never leave any fire unattended.

Never allow children to play near a fireplace, hot woodstove or any wood burning appliance.

Failure to follow these instructions and warnings, may result in an improper burn or risk of injury or fire.




Customers who viewed this have bought






FAQ Knowledge Base


There are no F.A.Q's at this time. If you have a question please click the Ask Question button above.

Get paid to promote this product

Learn More
 

Buyer Reviews

Lifetime Rating  

Write a Review

Positive

Fireplace Cleaning Logs


June Manning (West Orange, NJ)
Verified Member
Reviewed on Jan 14, 2013
such a great price, especially for how valuable their function is, cant get them at this price locally. Most the time, I cant even find them in the stores. Thanks so much and will buy again!


Positive

Works Great


Dustin Lofquist (Wapato, WA)
Verified Member
Reviewed on Dec 13, 2012
We recently purchased a older home after an inspection we were told that creosote a sweeping logs were a good investment. By using these logs we were able to clear out our chimney and no long have a safety hazard


Positive

Creosote Sweeping Log


Frank Fields (West Valley, NY)
Reviewed on Nov 26, 2012
The Creosote Sweeping Log works very well. They light readily and burn well it really helped me remove existing creosote on the inside of the stove and chimney. After I burned my first CSL the creosote hardened and fell off into the ash pile.